Fluke 719 100g pressure calibrator manual

Pressure Calibrator eBay

1010.1: 1992 EMC EN50082-1: 1992 and EN55022: 1994 Class B Size 216 mm x 94 mm x 66 mm (8.50 in x 3.72 in x 2.60 in) Weht 992 g (35 oz) Power, battery life 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718 Battery Life 4 to 20 hours typical, depending on functions used Warranty Three years (one year on pressure pump in Fluke 718) Display LCD, 5 dit pressure and current simultaneous Note For use with non-corrosive gasses Included Accessories: Protective Yellow Holster with test lead storage Instructions Sheet (14 languages) Test Leads and Allator Clip Two 9V alkaline batteries Pressure Calibrator -12 PSI to 30 PSI, (-850 mbar to 2 bar, -85 to 206.84 k Pa) NIST - Traceable calibration report and data Condition: Brand New Auction Details: Shipping: All domestic packages will be shipped out via Fedex, UPS, or USPS within the lower 48 states Shipping to Hawaii and Alaska would be extra, and those shipments will be shipped out via USPS priority mail, unless otherwise stated in the auction or negotiated in emails.

Fluke 719 Pressure Calibrator - Fluke Corporation

Over pressure per pressure module specs Resolution: Per pressure module specs Accuracy: To 0.025 % of full span, per pressure module specs Functions: Zero, Min, Max, Hold, Damp Note: media compatibility per pressure module specs Fluke 718 series via built in pump Range: -12 PSI or -850 mbar to full scale Supported Pressure Units; psi, in H20 (4 °C), in H20 (20 °C), cm H20 (4 °C), cm H20 (20 °C), bar, mbar, k Pa, in Hg, mm Hg, kg/cm Loop Power: Range: 24 V dc Accuracy: /- 10 % Note: Drive; 20 m A into 1000 Ω for battery 6.8V; 700 Ω for battery 5.8 to 6.8 V m A Measure: Range: 0 m A to 24 m A Resolution: 0.001 m A Accuracy: 0.015 % 1 count General Specifications Maximum voltage 30 volts: Non-operating Temperature -40 °C to 60 °C Operating Temperature -10 °C to 55° C Relative Humidity 95 % (10 °C to 30 °C); 75 % (30 °C to 40 °C); 45 % (40 °C to 50 °C); 35 % (50 °C to 55 °C) Operating Altitude 3,000 M max Shock 1 M drop test Vibration Random, 2 g, 5 Hz – 500 Hz Safety CSA C22.2 No.

<em>Fluke</em> 718-30G Portable Electric <em>Pressure</em> <em>Calibrator</em> W\ Vacuum.

Transcat 2009 April Supplement by Matt Gaston - issuu

The unique easy to clean pump helps protect the pump from damage and provides the ability to service the pump without disassembly, even in the field.

Fluke 718-30G Portable Electric Pressure Calibrator W\ Vacuum.

This compact pressure calibration solution is about a third of the size of comparable instruments and wehs just one kilogram (two pounds).


Fluke 719 100g pressure calibrator manual:

Rating: 100 / 100

Overall: 99 Rates